Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
All expressions used in PL/pgSQL statements are processed using the server's main SQL executor. For example, when you write a PL/pgSQL statement like
PL/pgSQL will evaluate the expression by feeding a query like
to the main SQL engine. While forming the SELECT
command, any occurrences of PL/pgSQL variable names are replaced by parameters, as discussed in detail in Section 42.11.1. This allows the query plan for the SELECT
to be prepared just once and then reused for subsequent evaluations with different values of the variables. Thus, what really happens on first use of an expression is essentially a PREPARE
command. For example, if we have declared two integer variables x
and y
, and we write
what happens behind the scenes is equivalent to
and then this prepared statement is EXECUTE
d for each execution of the IF
statement, with the current values of the PL/pgSQL variables supplied as parameter values. Normally these details are not important to a PL/pgSQL user, but they are useful to know when trying to diagnose a problem. More information appears in Section 42.11.2.
In this section and the following ones, we describe all the statement types that are explicitly understood by PL/pgSQL. Anything not recognized as one of these statement types is presumed to be an SQL command and is sent to the main database engine to execute, as described in and .
An assignment of a value to a PL/pgSQL variable is written as:
As explained previously, the expression in such a statement is evaluated by means of an SQL SELECT
command sent to the main database engine. The expression must yield a single value (possibly a row value, if the variable is a row or record variable). The target variable can be a simple variable (optionally qualified with a block name), a field of a row or record variable, or an element of an array that is a simple variable or field. Equal (=
) can be used instead of PL/SQL-compliant :=
.
If the expression's result data type doesn't match the variable's data type, the value will be coerced as though by an assignment cast (see ). If no assignment cast is known for the pair of data types involved, the PL/pgSQL interpreter will attempt to convert the result value textually, that is by applying the result type's output function followed by the variable type's input function. Note that this could result in run-time errors generated by the input function, if the string form of the result value is not acceptable to the input function.
Examples:
For any SQL command that does not return rows, for example INSERT
without a RETURNING
clause, you can execute the command within a PL/pgSQL function just by writing the command.
Any PL/pgSQL variable name appearing in the command text is treated as a parameter, and then the current value of the variable is provided as the parameter value at run time. This is exactly like the processing described earlier for expressions; for details see .
When executing a SQL command in this way, PL/pgSQL may cache and re-use the execution plan for the command, as discussed in .
Sometimes it is useful to evaluate an expression or SELECT
query but discard the result, for example when calling a function that has side-effects but no useful result value. To do this in PL/pgSQL, use the PERFORM
statement:
This executes query
and discards the result. Write the query
the same way you would write an SQL SELECT
command, but replace the initial keyword SELECT
with PERFORM
. For WITH
queries, use PERFORM
and then place the query in parentheses. (In this case, the query can only return one row.) PL/pgSQL variables will be substituted into the query just as for commands that return no result, and the plan is cached in the same way. Also, the special variable FOUND
is set to true if the query produced at least one row, or false if it produced no rows (see ).
One might expect that writing SELECT
directly would accomplish this result, but at present the only accepted way to do it is PERFORM
. A SQL command that can return rows, such as SELECT
, will be rejected as an error unless it has an INTO
clause as discussed in the next section.
An example:
The result of a SQL command yielding a single row (possibly of multiple columns) can be assigned to a record variable, row-type variable, or list of scalar variables. This is done by writing the base SQL command and adding an INTO
clause. For example,
where target
can be a record variable, a row variable, or a comma-separated list of simple variables and record/row fields. PL/pgSQL variables will be substituted into the rest of the query, and the plan is cached, just as described above for commands that do not return rows. This works for SELECT
, INSERT
/UPDATE
/DELETE
with RETURNING
, and utility commands that return row-set results (such as EXPLAIN
). Except for the INTO
clause, the SQL command is the same as it would be written outside PL/pgSQL.
Note that this interpretation of SELECT
with INTO
is quite different from PostgreSQL's regular SELECT INTO
command, wherein the INTO
target is a newly created table. If you want to create a table from a SELECT
result inside a PL/pgSQL function, use the syntax CREATE TABLE ... AS SELECT
.
If a row or a variable list is used as target, the query's result columns must exactly match the structure of the target as to number and data types, or else a run-time error occurs. When a record variable is the target, it automatically configures itself to the row type of the query result columns.
The INTO
clause can appear almost anywhere in the SQL command. Customarily it is written either just before or just after the list of select_expressions
in a SELECT
command, or at the end of the command for other command types. It is recommended that you follow this convention in case the PL/pgSQL parser becomes stricter in future versions.
If the STRICT
option is specified, the query must return exactly one row or a run-time error will be reported, either NO_DATA_FOUND
(no rows) or TOO_MANY_ROWS
(more than one row). You can use an exception block if you wish to catch the error, for example:
Successful execution of a command with STRICT
always sets FOUND
to true.
For INSERT
/UPDATE
/DELETE
with RETURNING
, PL/pgSQL reports an error for more than one returned row, even when STRICT
is not specified. This is because there is no option such as ORDER BY
with which to determine which affected row should be returned.
If print_strict_params
is enabled for the function, then when an error is thrown because the requirements of STRICT
are not met, the DETAIL
part of the error message will include information about the parameters passed to the query. You can change the print_strict_params
setting for all functions by setting plpgsql.print_strict_params
, though only subsequent function compilations will be affected. You can also enable it on a per-function basis by using a compiler option, for example:
On failure, this function might produce an error message such as
The STRICT
option matches the behavior of Oracle PL/SQL's SELECT INTO
and related statements.
where command-string
is an expression yielding a string (of type text
) containing the command to be executed. The optional target
is a record variable, a row variable, or a comma-separated list of simple variables and record/row fields, into which the results of the command will be stored. The optional USING
expressions supply values to be inserted into the command.
No substitution of PL/pgSQL variables is done on the computed command string. Any required variable values must be inserted in the command string as it is constructed; or you can use parameters as described below.
Also, there is no plan caching for commands executed via EXECUTE
. Instead, the command is always planned each time the statement is run. Thus the command string can be dynamically created within the function to perform actions on different tables and columns.
The INTO
clause specifies where the results of a SQL command returning rows should be assigned. If a row or variable list is provided, it must exactly match the structure of the query's results (when a record variable is used, it will configure itself to match the result structure automatically). If multiple rows are returned, only the first will be assigned to the INTO
variable. If no rows are returned, NULL is assigned to the INTO
variable(s). If no INTO
clause is specified, the query results are discarded.
If the STRICT
option is given, an error is reported unless the query produces exactly one row.
The command string can use parameter values, which are referenced in the command as $1
, $2
, etc. These symbols refer to values supplied in the USING
clause. This method is often preferable to inserting data values into the command string as text: it avoids run-time overhead of converting the values to text and back, and it is much less prone to SQL-injection attacks since there is no need for quoting or escaping. An example is:
Note that parameter symbols can only be used for data values — if you want to use dynamically determined table or column names, you must insert them into the command string textually. For example, if the preceding query needed to be done against a dynamically selected table, you could do this:
A cleaner approach is to use format()
's %I
specification for table or column names (strings separated by a newline are concatenated):
Another restriction on parameter symbols is that they only work in SELECT
, INSERT
, UPDATE
, and DELETE
commands. In other statement types (generically called utility statements), you must insert values textually even if they are just data values.
An EXECUTE
with a simple constant command string and some USING
parameters, as in the first example above, is functionally equivalent to just writing the command directly in PL/pgSQL and allowing replacement of PL/pgSQL variables to happen automatically. The important difference is that EXECUTE
will re-plan the command on each execution, generating a plan that is specific to the current parameter values; whereas PL/pgSQL may otherwise create a generic plan and cache it for re-use. In situations where the best plan depends strongly on the parameter values, it can be helpful to use EXECUTE
to positively ensure that a generic plan is not selected.
SELECT INTO
is not currently supported within EXECUTE
; instead, execute a plain SELECT
command and specify INTO
as part of the EXECUTE
itself.
Example 42.1. Quoting Values in Dynamic Queries
Dynamic values require careful handling since they might contain quote characters. An example using format()
(this assumes that you are dollar quoting the function body so quote marks need not be doubled):
It is also possible to call the quoting functions directly:
Because quote_literal
is labeled STRICT
, it will always return null when called with a null argument. In the above example, if newvalue
or keyvalue
were null, the entire dynamic query string would become null, leading to an error from EXECUTE
. You can avoid this problem by using the quote_nullable
function, which works the same as quote_literal
except that when called with a null argument it returns the string NULL
. For example,
If you are dealing with values that might be null, you should usually use quote_nullable
in place of quote_literal
.
As always, care must be taken to ensure that null values in a query do not deliver unintended results. For example the WHERE
clause
will never succeed if keyvalue
is null, because the result of using the equality operator =
with a null operand is always null. If you wish null to work like an ordinary key value, you would need to rewrite the above as
Note that dollar quoting is only useful for quoting fixed text. It would be a very bad idea to try to write this example as:
because it would break if the contents of newvalue
happened to contain $$
. The same objection would apply to any other dollar-quoting delimiter you might pick. So, to safely quote text that is not known in advance, you must use quote_literal
, quote_nullable
, or quote_ident
, as appropriate.
%I
is equivalent to quote_ident
, and %L
is equivalent to quote_nullable
. The format
function can be used in conjunction with the USING
clause:
This form is better because the variables are handled in their native data type format, rather than unconditionally converting them to text and quoting them via %L
. It is also more efficient.
There are several ways to determine the effect of a command. The first method is to use the GET DIAGNOSTICS
command, which has the form:
Table 42.1. Available Diagnostics Items
The second method to determine the effects of a command is to check the special variable named FOUND
, which is of type boolean
. FOUND
starts out false within each PL/pgSQL function call. It is set by each of the following types of statements:
A SELECT INTO
statement sets FOUND
true if a row is assigned, false if no row is returned.
A PERFORM
statement sets FOUND
true if it produces (and discards) one or more rows, false if no row is produced.
UPDATE
, INSERT
, and DELETE
statements set FOUND
true if at least one row is affected, false if no row is affected.
A FETCH
statement sets FOUND
true if it returns a row, false if no row is returned.
A MOVE
statement sets FOUND
true if it successfully repositions the cursor, false otherwise.
A FOR
or FOREACH
statement sets FOUND
true if it iterates one or more times, else false. FOUND
is set this way when the loop exits; inside the execution of the loop, FOUND
is not modified by the loop statement, although it might be changed by the execution of other statements within the loop body.
RETURN QUERY
and RETURN QUERY EXECUTE
statements set FOUND
true if the query returns at least one row, false if no row is returned.
Other PL/pgSQL statements do not change the state of FOUND
. Note in particular that EXECUTE
changes the output of GET DIAGNOSTICS
, but does not change FOUND
.
FOUND
is a local variable within each PL/pgSQL function; any changes to it affect only the current function.
Sometimes a placeholder statement that does nothing is useful. For example, it can indicate that one arm of an if/then/else chain is deliberately empty. For this purpose, use the NULL
statement:
For example, the following two fragments of code are equivalent:
Which is preferable is a matter of taste.
In Oracle's PL/SQL, empty statement lists are not allowed, and so NULL
statements are required for situations such as this. PL/pgSQL allows you to just write nothing, instead.
If STRICT
is not specified in the INTO
clause, then target
will be set to the first row returned by the query, or to nulls if the query returned no rows. (Note that “the first row” is not well-defined unless you've used ORDER BY
.) Any result rows after the first row are discarded. You can check the special FOUND
variable (see ) to determine whether a row was returned:
To handle cases where you need to process multiple result rows from a SQL query, see .
Oftentimes you will want to generate dynamic commands inside your PL/pgSQL functions, that is, commands that will involve different tables or different data types each time they are executed. PL/pgSQL's normal attempts to cache plans for commands (as discussed in ) will not work in such scenarios. To handle this sort of problem, the EXECUTE
statement is provided:
The PL/pgSQL EXECUTE
statement is not related to the SQL statement supported by the PostgreSQL server. The server's EXECUTE
statement cannot be used directly within PL/pgSQL functions (and is not needed).
When working with dynamic commands you will often have to handle escaping of single quotes. The recommended method for quoting fixed text in your function body is dollar quoting. (If you have legacy code that does not use dollar quoting, please refer to the overview in , which can save you some effort when translating said code to a more reasonable scheme.)
This example demonstrates the use of the quote_ident
and quote_literal
functions (see ). For safety, expressions containing column or table identifiers should be passed through quote_ident
before insertion in a dynamic query. Expressions containing values that should be literal strings in the constructed command should be passed through quote_literal
. These functions take the appropriate steps to return the input text enclosed in double or single quotes respectively, with any embedded special characters properly escaped.
(At present, IS NOT DISTINCT FROM
is handled much less efficiently than =
, so don't do this unless you must. See for more information on nulls and IS DISTINCT
.)
Dynamic SQL statements can also be safely constructed using the format
function (see ). For example:
A much larger example of a dynamic command and EXECUTE
can be seen in , which builds and executes a CREATE FUNCTION
command to define a new function.
This command allows retrieval of system status indicators. CURRENT
is a noise word (but see also GET STACKED DIAGNOSTICS
in ). Each item
is a key word identifying a status value to be assigned to the specified variable
(which should be of the right data type to receive it). The currently available status items are shown in . Colon-equal (:=
) can be used instead of the SQL-standard =
token. An example:
All variables used in a block must be declared in the declarations section of the block. (The only exceptions are that the loop variable of a FOR
loop iterating over a range of integer values is automatically declared as an integer variable, and likewise the loop variable of a FOR
loop iterating over a cursor's result is automatically declared as a record variable.)
PL/pgSQL variables can have any SQL data type, such as integer
, varchar
, and char
.
Here are some examples of variable declarations:
The general syntax of a variable declaration is:
The DEFAULT
clause, if given, specifies the initial value assigned to the variable when the block is entered. If the DEFAULT
clause is not given then the variable is initialized to the SQL null value. The CONSTANT
option prevents the variable from being assigned to after initialization, so that its value will remain constant for the duration of the block. The COLLATE
option specifies a collation to use for the variable (see Section 42.3.6). If NOT NULL
is specified, an assignment of a null value results in a run-time error. All variables declared as NOT NULL
must have a nonnull default value specified. Equal (=
) can be used instead of PL/SQL-compliant :=
.
A variable's default value is evaluated and assigned to the variable each time the block is entered (not just once per function call). So, for example, assigning now()
to a variable of type timestamp
causes the variable to have the time of the current function call, not the time when the function was precompiled.
Examples:
Parameters passed to functions are named with the identifiers $1
, $2
, etc. Optionally, aliases can be declared for $
n
parameter names for increased readability. Either the alias or the numeric identifier can then be used to refer to the parameter value.
There are two ways to create an alias. The preferred way is to give a name to the parameter in the CREATE FUNCTION
command, for example:
The other way is to explicitly declare an alias, using the declaration syntax
The same example in this style looks like:
These two examples are not perfectly equivalent. In the first case, subtotal
could be referenced as sales_tax.subtotal
, but in the second case it could not. (Had we attached a label to the inner block, subtotal
could be qualified with that label, instead.)
Some more examples:
When a PL/pgSQL function is declared with output parameters, the output parameters are given $
n
names and optional aliases in just the same way as the normal input parameters. An output parameter is effectively a variable that starts out NULL; it should be assigned to during the execution of the function. The final value of the parameter is what is returned. For instance, the sales-tax example could also be done this way:
Notice that we omitted RETURNS real
— we could have included it, but it would be redundant.
Output parameters are most useful when returning multiple values. A trivial example is:
As discussed in Section 37.5.4, this effectively creates an anonymous record type for the function's results. If a RETURNS
clause is given, it must say RETURNS record
.
Another way to declare a PL/pgSQL function is with RETURNS TABLE
, for example:
This is exactly equivalent to declaring one or more OUT
parameters and specifying RETURNS SETOF
sometype
.
When the return type of a PL/pgSQL function is declared as a polymorphic type (see Section 37.2.5), a special parameter $0
is created. Its data type is the actual return type of the function, as deduced from the actual input types. This allows the function to access its actual return type as shown in Section 42.3.3. $0
is initialized to null and can be modified by the function, so it can be used to hold the return value if desired, though that is not required. $0
can also be given an alias. For example, this function works on any data type that has a +
operator:
The same effect can be obtained by declaring one or more output parameters as polymorphic types. In this case the special $0
parameter is not used; the output parameters themselves serve the same purpose. For example:
In practice it might be more useful to declare a polymorphic function using the anycompatible
family of types, so that automatic promotion of the input arguments to a common type will occur. For example:
With this example, a call such as
will work, automatically promoting the integer inputs to numeric. The function using anyelement
would require you to cast the three inputs to the same type manually.
ALIAS
The ALIAS
syntax is more general than is suggested in the previous section: you can declare an alias for any variable, not just function parameters. The main practical use for this is to assign a different name for variables with predetermined names, such as NEW
or OLD
within a trigger function.
Examples:
Since ALIAS
creates two different ways to name the same object, unrestricted use can be confusing. It's best to use it only for the purpose of overriding predetermined names.
%TYPE
provides the data type of a variable or table column. You can use this to declare variables that will hold database values. For example, let's say you have a column named user_id
in your users
table. To declare a variable with the same data type as users.user_id
you write:
By using %TYPE
you don't need to know the data type of the structure you are referencing, and most importantly, if the data type of the referenced item changes in the future (for instance: you change the type of user_id
from integer
to real
), you might not need to change your function definition.
%TYPE
is particularly valuable in polymorphic functions, since the data types needed for internal variables can change from one call to the next. Appropriate variables can be created by applying %TYPE
to the function's arguments or result placeholders.
A variable of a composite type is called a row variable (or row-type variable). Such a variable can hold a whole row of a SELECT
or FOR
query result, so long as that query's column set matches the declared type of the variable. The individual fields of the row value are accessed using the usual dot notation, for example rowvar.field
.
A row variable can be declared to have the same type as the rows of an existing table or view, by using the table_name
%ROWTYPE
notation; or it can be declared by giving a composite type's name. (Since every table has an associated composite type of the same name, it actually does not matter in PostgreSQL whether you write %ROWTYPE
or not. But the form with %ROWTYPE
is more portable.)
Parameters to a function can be composite types (complete table rows). In that case, the corresponding identifier $
n
will be a row variable, and fields can be selected from it, for example $1.user_id
.
Here is an example of using composite types. table1
and table2
are existing tables having at least the mentioned fields:
Record variables are similar to row-type variables, but they have no predefined structure. They take on the actual row structure of the row they are assigned during a SELECT
or FOR
command. The substructure of a record variable can change each time it is assigned to. A consequence of this is that until a record variable is first assigned to, it has no substructure, and any attempt to access a field in it will draw a run-time error.
Note that RECORD
is not a true data type, only a placeholder. One should also realize that when a PL/pgSQL function is declared to return type record
, this is not quite the same concept as a record variable, even though such a function might use a record variable to hold its result. In both cases the actual row structure is unknown when the function is written, but for a function returning record
the actual structure is determined when the calling query is parsed, whereas a record variable can change its row structure on-the-fly.
When a PL/pgSQL function has one or more parameters of collatable data types, a collation is identified for each function call depending on the collations assigned to the actual arguments, as described in Section 23.2. If a collation is successfully identified (i.e., there are no conflicts of implicit collations among the arguments) then all the collatable parameters are treated as having that collation implicitly. This will affect the behavior of collation-sensitive operations within the function. For example, consider
The first use of less_than
will use the common collation of text_field_1
and text_field_2
for the comparison, while the second use will use C
collation.
Furthermore, the identified collation is also assumed as the collation of any local variables that are of collatable types. Thus this function would not work any differently if it were written as
If there are no parameters of collatable data types, or no common collation can be identified for them, then parameters and local variables use the default collation of their data type (which is usually the database's default collation, but could be different for variables of domain types).
A local variable of a collatable data type can have a different collation associated with it by including the COLLATE
option in its declaration, for example
This option overrides the collation that would otherwise be given to the variable according to the rules above.
Also, of course explicit COLLATE
clauses can be written inside a function if it is desired to force a particular collation to be used in a particular operation. For example,
This overrides the collations associated with the table columns, parameters, or local variables used in the expression, just as would happen in a plain SQL command.
PL/pgSQL is a loadable procedural language for the PostgreSQL database system. The design goals of PL/pgSQL were to create a loadable procedural language that
can be used to create functions and triggers,
adds control structures to the SQL language,
can perform complex computations,
inherits all user-defined types, functions, and operators,
can be defined to be trusted by the server,
is easy to use.
Functions created with PL/pgSQL can be used anywhere that built-in functions could be used. For example, it is possible to create complex conditional computation functions and later use them to define operators or use them in index expressions.
In PostgreSQL 9.0 and later, PL/pgSQL is installed by default. However it is still a loadable module, so especially security-conscious administrators could choose to remove it.
SQL is the language PostgreSQL and most other relational databases use as query language. It's portable and easy to learn. But every SQL statement must be executed individually by the database server.
That means that your client application must send each query to the database server, wait for it to be processed, receive and process the results, do some computation, then send further queries to the server. All this incurs interprocess communication and will also incur network overhead if your client is on a different machine than the database server.
With PL/pgSQL you can group a block of computation and a series of queries inside the database server, thus having the power of a procedural language and the ease of use of SQL, but with considerable savings of client/server communication overhead.
Extra round trips between client and server are eliminated
Intermediate results that the client does not need do not have to be marshaled or transferred between server and client
Multiple rounds of query parsing can be avoided
This can result in a considerable performance increase as compared to an application that does not use stored functions.
Also, with PL/pgSQL you can use all the data types, operators and functions of SQL.
Functions written in PL/pgSQL can accept as arguments any scalar or array data type supported by the server, and they can return a result of any of these types. They can also accept or return any composite type (row type) specified by name. It is also possible to declare a PL/pgSQL function as accepting record
, which means that any composite type will do as input, or as returning record
, which means that the result is a row type whose columns are determined by specification in the calling query, as discussed in Section 7.2.1.4.
PL/pgSQL functions can be declared to accept a variable number of arguments by using the VARIADIC
marker. This works exactly the same way as for SQL functions, as discussed in Section 37.5.5.
PL/pgSQL functions can also be declared to accept and return the polymorphic types described in Section 37.2.5, thus allowing the actual data types handled by the function to vary from call to call. Examples appear in Section 42.3.1.
PL/pgSQL functions can also be declared to return a “set” (or table) of any data type that can be returned as a single instance. Such a function generates its output by executing RETURN NEXT
for each desired element of the result set, or by using RETURN QUERY
to output the result of evaluating a query.
Finally, a PL/pgSQL function can be declared to return void
if it has no useful return value. (Alternatively, it could be written as a procedure in that case.)
PL/pgSQL functions can also be declared with output parameters in place of an explicit specification of the return type. This does not add any fundamental capability to the language, but it is often convenient, especially for returning multiple values. The RETURNS TABLE
notation can also be used in place of RETURNS SETOF
.
Specific examples appear in Section 42.3.1 and Section 42.6.1.
Name | Type | Description |
|
| the number of rows processed by the most recent SQL command |
|
|
Control structures are probably the most useful (and important) part of PL/pgSQL. With PL/pgSQL's control structures, you can manipulate PostgreSQL data in a very flexible and powerful way.
There are two commands available that allow you to return data from a function: RETURN
and RETURN NEXT
.
RETURN
with an expression terminates the function and returns the value of expression
to the caller. This form is used for PL/pgSQL functions that do not return a set.
In a function that returns a scalar type, the expression's result will automatically be cast into the function's return type as described for assignments. But to return a composite (row) value, you must write an expression delivering exactly the requested column set. This may require use of explicit casting.
If you declared the function with output parameters, write just RETURN
with no expression. The current values of the output parameter variables will be returned.
If you declared the function to return void
, a RETURN
statement can be used to exit the function early; but do not write an expression following RETURN
.
The return value of a function cannot be left undefined. If control reaches the end of the top-level block of the function without hitting a RETURN
statement, a run-time error will occur. This restriction does not apply to functions with output parameters and functions returning void
, however. In those cases a RETURN
statement is automatically executed if the top-level block finishes.
Some examples:
When a PL/pgSQL function is declared to return SETOF
sometype
, the procedure to follow is slightly different. In that case, the individual items to return are specified by a sequence of RETURN NEXT
or RETURN QUERY
commands, and then a final RETURN
command with no argument is used to indicate that the function has finished executing. RETURN NEXT
can be used with both scalar and composite data types; with a composite result type, an entire “table” of results will be returned. RETURN QUERY
appends the results of executing a query to the function's result set. RETURN NEXT
and RETURN QUERY
can be freely intermixed in a single set-returning function, in which case their results will be concatenated.
RETURN NEXT
and RETURN QUERY
do not actually return from the function — they simply append zero or more rows to the function's result set. Execution then continues with the next statement in the PL/pgSQL function. As successive RETURN NEXT
or RETURN QUERY
commands are executed, the result set is built up. A final RETURN
, which should have no argument, causes control to exit the function (or you can just let control reach the end of the function).
RETURN QUERY
has a variant RETURN QUERY EXECUTE
, which specifies the query to be executed dynamically. Parameter expressions can be inserted into the computed query string via USING
, in just the same way as in the EXECUTE
command.
If you declared the function with output parameters, write just RETURN NEXT
with no expression. On each execution, the current values of the output parameter variable(s) will be saved for eventual return as a row of the result. Note that you must declare the function as returning SETOF record
when there are multiple output parameters, or SETOF
sometype
when there is just one output parameter of type sometype
, in order to create a set-returning function with output parameters.
Here is an example of a function using RETURN NEXT
:
Here is an example of a function using RETURN QUERY
:
The current implementation of RETURN NEXT
and RETURN QUERY
stores the entire result set before returning from the function, as discussed above. That means that if a PL/pgSQL function produces a very large result set, performance might be poor: data will be written to disk to avoid memory exhaustion, but the function itself will not return until the entire result set has been generated. A future version of PL/pgSQL might allow users to define set-returning functions that do not have this limitation. Currently, the point at which data begins being written to disk is controlled by the work_mem configuration variable. Administrators who have sufficient memory to store larger result sets in memory should consider increasing this parameter.
A procedure does not have a return value. A procedure can therefore end without a RETURN
statement. If you wish to use a RETURN
statement to exit the code early, write just RETURN
with no expression.
If the procedure has output parameters, the final values of the output parameter variables will be returned to the caller.
A PL/pgSQL function, procedure, or DO
block can call a procedure using CALL
. Output parameters are handled differently from the way that CALL
works in plain SQL. Each INOUT
parameter of the procedure must correspond to a variable in the CALL
statement, and whatever the procedure returns is assigned back to that variable after it returns. For example:
IF
and CASE
statements let you execute alternative commands based on certain conditions. PL/pgSQL has three forms of IF
:
IF ... THEN ... END IF
IF ... THEN ... ELSE ... END IF
IF ... THEN ... ELSIF ... THEN ... ELSE ... END IF
and two forms of CASE
:
CASE ... WHEN ... THEN ... ELSE ... END CASE
CASE WHEN ... THEN ... ELSE ... END CASE
IF-THEN
statements are the simplest form of IF
. The statements between THEN
and END IF
will be executed if the condition is true. Otherwise, they are skipped.
Example:
IF-THEN-ELSE
statements add to IF-THEN
by letting you specify an alternative set of statements that should be executed if the condition is not true. (Note this includes the case where the condition evaluates to NULL.)
Examples:
Sometimes there are more than just two alternatives. IF-THEN-ELSIF
provides a convenient method of checking several alternatives in turn. The IF
conditions are tested successively until the first one that is true is found. Then the associated statement(s) are executed, after which control passes to the next statement after END IF
. (Any subsequent IF
conditions are not tested.) If none of the IF
conditions is true, then the ELSE
block (if any) is executed.
Here is an example:
The key word ELSIF
can also be spelled ELSEIF
.
An alternative way of accomplishing the same task is to nest IF-THEN-ELSE
statements, as in the following example:
However, this method requires writing a matching END IF
for each IF
, so it is much more cumbersome than using ELSIF
when there are many alternatives.
The simple form of CASE
provides conditional execution based on equality of operands. The search-expression
is evaluated (once) and successively compared to each expression
in the WHEN
clauses. If a match is found, then the corresponding statements
are executed, and then control passes to the next statement after END CASE
. (Subsequent WHEN
expressions are not evaluated.) If no match is found, the ELSE
statements
are executed; but if ELSE
is not present, then a CASE_NOT_FOUND
exception is raised.
Here is a simple example:
The searched form of CASE
provides conditional execution based on truth of Boolean expressions. Each WHEN
clause's boolean-expression
is evaluated in turn, until one is found that yields true
. Then the corresponding statements
are executed, and then control passes to the next statement after END CASE
. (Subsequent WHEN
expressions are not evaluated.) If no true result is found, the ELSE
statements
are executed; but if ELSE
is not present, then a CASE_NOT_FOUND
exception is raised.
Here is an example:
This form of CASE
is entirely equivalent to IF-THEN-ELSIF
, except for the rule that reaching an omitted ELSE
clause results in an error rather than doing nothing.
With the LOOP
, EXIT
, CONTINUE
, WHILE
, FOR
, and FOREACH
statements, you can arrange for your PL/pgSQL function to repeat a series of commands.
LOOP
defines an unconditional loop that is repeated indefinitely until terminated by an EXIT
or RETURN
statement. The optional label
can be used by EXIT
and CONTINUE
statements within nested loops to specify which loop those statements refer to.
If no label
is given, the innermost loop is terminated and the statement following END LOOP
is executed next. If label
is given, it must be the label of the current or some outer level of nested loop or block. Then the named loop or block is terminated and control continues with the statement after the loop's/block's corresponding END
.
If WHEN
is specified, the loop exit occurs only if boolean-expression
is true. Otherwise, control passes to the statement after EXIT
.
EXIT
can be used with all types of loops; it is not limited to use with unconditional loops.
When used with a BEGIN
block, EXIT
passes control to the next statement after the end of the block. Note that a label must be used for this purpose; an unlabeled EXIT
is never considered to match a BEGIN
block. (This is a change from pre-8.4 releases of PostgreSQL, which would allow an unlabeled EXIT
to match a BEGIN
block.)
Examples:
If no label
is given, the next iteration of the innermost loop is begun. That is, all statements remaining in the loop body are skipped, and control returns to the loop control expression (if any) to determine whether another loop iteration is needed. If label
is present, it specifies the label of the loop whose execution will be continued.
If WHEN
is specified, the next iteration of the loop is begun only if boolean-expression
is true. Otherwise, control passes to the statement after CONTINUE
.
CONTINUE
can be used with all types of loops; it is not limited to use with unconditional loops.
Examples:
The WHILE
statement repeats a sequence of statements so long as the boolean-expression
evaluates to true. The expression is checked just before each entry to the loop body.
For example:
This form of FOR
creates a loop that iterates over a range of integer values. The variable name
is automatically defined as type integer
and exists only inside the loop (any existing definition of the variable name is ignored within the loop). The two expressions giving the lower and upper bound of the range are evaluated once when entering the loop. If the BY
clause isn't specified the iteration step is 1, otherwise it's the value specified in the BY
clause, which again is evaluated once on loop entry. If REVERSE
is specified then the step value is subtracted, rather than added, after each iteration.
Some examples of integer FOR
loops:
If the lower bound is greater than the upper bound (or less than, in the REVERSE
case), the loop body is not executed at all. No error is raised.
If a label
is attached to the FOR
loop then the integer loop variable can be referenced with a qualified name, using that label
.
Using a different type of FOR
loop, you can iterate through the results of a query and manipulate that data accordingly. The syntax is:
The target
is a record variable, row variable, or comma-separated list of scalar variables. The target
is successively assigned each row resulting from the query
and the loop body is executed for each row. Here is an example:
If the loop is terminated by an EXIT
statement, the last assigned row value is still accessible after the loop.
The query
used in this type of FOR
statement can be any SQL command that returns rows to the caller: SELECT
is the most common case, but you can also use INSERT
, UPDATE
, or DELETE
with a RETURNING
clause. Some utility commands such as EXPLAIN
will work too.
PL/pgSQL variables are substituted into the query text, and the query plan is cached for possible re-use, as discussed in detail in Section 42.11.1 and Section 42.11.2.
The FOR-IN-EXECUTE
statement is another way to iterate over rows:
This is like the previous form, except that the source query is specified as a string expression, which is evaluated and replanned on each entry to the FOR
loop. This allows the programmer to choose the speed of a preplanned query or the flexibility of a dynamic query, just as with a plain EXECUTE
statement. As with EXECUTE
, parameter values can be inserted into the dynamic command via USING
.
Another way to specify the query whose results should be iterated through is to declare it as a cursor. This is described in Section 42.7.4.
The FOREACH
loop is much like a FOR
loop, but instead of iterating through the rows returned by a SQL query, it iterates through the elements of an array value. (In general, FOREACH
is meant for looping through components of a composite-valued expression; variants for looping through composites besides arrays may be added in future.) The FOREACH
statement to loop over an array is:
Without SLICE
, or if SLICE 0
is specified, the loop iterates through individual elements of the array produced by evaluating the expression
. The target
variable is assigned each element value in sequence, and the loop body is executed for each element. Here is an example of looping through the elements of an integer array:
The elements are visited in storage order, regardless of the number of array dimensions. Although the target
is usually just a single variable, it can be a list of variables when looping through an array of composite values (records). In that case, for each array element, the variables are assigned from successive columns of the composite value.
With a positive SLICE
value, FOREACH
iterates through slices of the array rather than single elements. The SLICE
value must be an integer constant not larger than the number of dimensions of the array. The target
variable must be an array, and it receives successive slices of the array value, where each slice is of the number of dimensions specified by SLICE
. Here is an example of iterating through one-dimensional slices:
By default, any error occurring in a PL/pgSQL function aborts execution of the function, and indeed of the surrounding transaction as well. You can trap errors and recover from them by using a BEGIN
block with an EXCEPTION
clause. The syntax is an extension of the normal syntax for a BEGIN
block:
If no error occurs, this form of block simply executes all the statements
, and then control passes to the next statement after END
. But if an error occurs within the statements
, further processing of the statements
is abandoned, and control passes to the EXCEPTION
list. The list is searched for the first condition
matching the error that occurred. If a match is found, the corresponding handler_statements
are executed, and then control passes to the next statement after END
. If no match is found, the error propagates out as though the EXCEPTION
clause were not there at all: the error can be caught by an enclosing block with EXCEPTION
, or if there is none it aborts processing of the function.
The condition
names can be any of those shown in Appendix A. A category name matches any error within its category. The special condition name OTHERS
matches every error type except QUERY_CANCELED
and ASSERT_FAILURE
. (It is possible, but often unwise, to trap those two error types by name.) Condition names are not case-sensitive. Also, an error condition can be specified by SQLSTATE
code; for example these are equivalent:
If a new error occurs within the selected handler_statements
, it cannot be caught by this EXCEPTION
clause, but is propagated out. A surrounding EXCEPTION
clause could catch it.
When an error is caught by an EXCEPTION
clause, the local variables of the PL/pgSQL function remain as they were when the error occurred, but all changes to persistent database state within the block are rolled back. As an example, consider this fragment:
When control reaches the assignment to y
, it will fail with a division_by_zero
error. This will be caught by the EXCEPTION
clause. The value returned in the RETURN
statement will be the incremented value of x
, but the effects of the UPDATE
command will have been rolled back. The INSERT
command preceding the block is not rolled back, however, so the end result is that the database contains Tom Jones
not Joe Jones
.
A block containing an EXCEPTION
clause is significantly more expensive to enter and exit than a block without one. Therefore, don't use EXCEPTION
without need.
UPDATE
/INSERT
This example uses exception handling to perform either UPDATE
or INSERT
, as appropriate. It is recommended that applications use INSERT
with ON CONFLICT DO UPDATE
rather than actually using this pattern. This example serves primarily to illustrate use of PL/pgSQL control flow structures:
This coding assumes the unique_violation
error is caused by the INSERT
, and not by, say, an INSERT
in a trigger function on the table. It might also misbehave if there is more than one unique index on the table, since it will retry the operation regardless of which index caused the error. More safety could be had by using the features discussed next to check that the trapped error was the one expected.
Exception handlers frequently need to identify the specific error that occurred. There are two ways to get information about the current exception in PL/pgSQL: special variables and the GET STACKED DIAGNOSTICS
command.
Within an exception handler, the special variable SQLSTATE
contains the error code that corresponds to the exception that was raised (refer to Table A.1 for a list of possible error codes). The special variable SQLERRM
contains the error message associated with the exception. These variables are undefined outside exception handlers.
Within an exception handler, one may also retrieve information about the current exception by using the GET STACKED DIAGNOSTICS
command, which has the form:
Each item
is a key word identifying a status value to be assigned to the specified variable
(which should be of the right data type to receive it). The currently available status items are shown in Table 42.2.
If the exception did not set a value for an item, an empty string will be returned.
Here is an example:
The GET DIAGNOSTICS
command, previously described in Section 42.5.5, retrieves information about current execution state (whereas the GET STACKED DIAGNOSTICS
command discussed above reports information about the execution state as of a previous error). Its PG_CONTEXT
status item is useful for identifying the current execution location. PG_CONTEXT
returns a text string with line(s) of text describing the call stack. The first line refers to the current function and currently executing GET DIAGNOSTICS
command. The second and any subsequent lines refer to calling functions further up the call stack. For example:
GET STACKED DIAGNOSTICS ... PG_EXCEPTION_CONTEXT
returns the same sort of stack trace, but describing the location at which an error was detected, rather than the current location.
Functions written in PL/pgSQL are defined to the server by executing commands. Such a command would normally look like, say,
The function body is simply a string literal so far as CREATE FUNCTION
is concerned. It is often helpful to use dollar quoting (see ) to write the function body, rather than the normal single quote syntax. Without dollar quoting, any single quotes or backslashes in the function body must be escaped by doubling them. Almost all the examples in this chapter use dollar-quoted literals for their function bodies.
PL/pgSQL is a block-structured language. The complete text of a function body must be a block. A block is defined as:
Each declaration and each statement within a block is terminated by a semicolon. A block that appears within another block must have a semicolon after END
, as shown above; however the final END
that concludes a function body does not require a semicolon.
A common mistake is to write a semicolon immediately after BEGIN
. This is incorrect and will result in a syntax error.
A label
is only needed if you want to identify the block for use in an EXIT
statement, or to qualify the names of the variables declared in the block. If a label is given after END
, it must match the label at the block's beginning.
All key words are case-insensitive. Identifiers are implicitly converted to lower case unless double-quoted, just as they are in ordinary SQL commands.
Comments work the same way in PL/pgSQL code as in ordinary SQL. A double dash (--
) starts a comment that extends to the end of the line. A /*
starts a block comment that extends to the matching occurrence of */
. Block comments nest.
Any statement in the statement section of a block can be a subblock. Subblocks can be used for logical grouping or to localize variables to a small group of statements. Variables declared in a subblock mask any similarly-named variables of outer blocks for the duration of the subblock; but you can access the outer variables anyway if you qualify their names with their block's label. For example:
line(s) of text describing the current call stack (see )
There is actually a hidden “outer block” surrounding the body of any PL/pgSQL function. This block provides the declarations of the function's parameters (if any), as well as some special variables such as FOUND
(see ). The outer block is labeled with the function's name, meaning that parameters and special variables can be qualified with the function's name.
It is important not to confuse the use of BEGIN
/END
for grouping statements in PL/pgSQL with the similarly-named SQL commands for transaction control. PL/pgSQL's BEGIN
/END
are only for grouping; they do not start or end a transaction. See for information on managing transactions in PL/pgSQL. Also, a block containing an EXCEPTION
clause effectively forms a subtransaction that can be rolled back without affecting the outer transaction. For more about that see .
Name
Type
Description
RETURNED_SQLSTATE
text
the SQLSTATE error code of the exception
COLUMN_NAME
text
the name of the column related to exception
CONSTRAINT_NAME
text
the name of the constraint related to exception
PG_DATATYPE_NAME
text
the name of the data type related to exception
MESSAGE_TEXT
text
the text of the exception's primary message
TABLE_NAME
text
the name of the table related to exception
SCHEMA_NAME
text
the name of the schema related to exception
PG_EXCEPTION_DETAIL
text
the text of the exception's detail message, if any
PG_EXCEPTION_HINT
text
the text of the exception's hint message, if any
PG_EXCEPTION_CONTEXT
text
line(s) of text describing the call stack at the time of the exception (see Section 42.6.9)