This section discusses some implementation details that are frequently important for PL/pgSQL users to know.
SQL statements and expressions within a PL/pgSQL function can refer to variables and parameters of the function. Behind the scenes, PL/pgSQL substitutes query parameters for such references. Query parameters will only be substituted in places where they are syntactically permissible. As an extreme case, consider this example of poor programming style:
The first occurrence of foo
must syntactically be a table name, so it will not be substituted, even if the function has a variable named foo
. The second occurrence must be the name of a column of that table, so it will not be substituted either. Likewise the third occurrence must be a function name, so it also will not be substituted for. Only the last occurrence is a candidate to be a reference to a variable of the PL/pgSQL function.
Another way to understand this is that variable substitution can only insert data values into an SQL command; it cannot dynamically change which database objects are referenced by the command. (If you want to do that, you must build a command string dynamically, as explained in Section 43.5.4.)
Since the names of variables are syntactically no different from the names of table columns, there can be ambiguity in statements that also refer to tables: is a given name meant to refer to a table column, or a variable? Let's change the previous example to
Here, dest
and src
must be table names, and col
must be a column of dest
, but foo
and bar
might reasonably be either variables of the function or columns of src
.
By default, PL/pgSQL will report an error if a name in an SQL statement could refer to either a variable or a table column. You can fix such a problem by renaming the variable or column, or by qualifying the ambiguous reference, or by telling PL/pgSQL which interpretation to prefer.
The simplest solution is to rename the variable or column. A common coding rule is to use a different naming convention for PL/pgSQL variables than you use for column names. For example, if you consistently name function variables v_
something
while none of your column names start with v_
, no conflicts will occur.
Alternatively you can qualify ambiguous references to make them clear. In the above example, src.foo
would be an unambiguous reference to the table column. To create an unambiguous reference to a variable, declare it in a labeled block and use the block's label (see Section 43.2). For example,
Here block.foo
means the variable even if there is a column foo
in src
. Function parameters, as well as special variables such as FOUND
, can be qualified by the function's name, because they are implicitly declared in an outer block labeled with the function's name.
Sometimes it is impractical to fix all the ambiguous references in a large body of PL/pgSQL code. In such cases you can specify that PL/pgSQL should resolve ambiguous references as the variable (which is compatible with PL/pgSQL's behavior before PostgreSQL 9.0), or as the table column (which is compatible with some other systems such as Oracle).
To change this behavior on a system-wide basis, set the configuration parameter plpgsql.variable_conflict
to one of error
, use_variable
, or use_column
(where error
is the factory default). This parameter affects subsequent compilations of statements in PL/pgSQL functions, but not statements already compiled in the current session. Because changing this setting can cause unexpected changes in the behavior of PL/pgSQL functions, it can only be changed by a superuser.
You can also set the behavior on a function-by-function basis, by inserting one of these special commands at the start of the function text:
These commands affect only the function they are written in, and override the setting of plpgsql.variable_conflict
. An example is
In the UPDATE
command, curtime
, comment
, and id
will refer to the function's variable and parameters whether or not users
has columns of those names. Notice that we had to qualify the reference to users.id
in the WHERE
clause to make it refer to the table column. But we did not have to qualify the reference to comment
as a target in the UPDATE
list, because syntactically that must be a column of users
. We could write the same function without depending on the variable_conflict
setting in this way:
Variable substitution does not happen in a command string given to EXECUTE
or one of its variants. If you need to insert a varying value into such a command, do so as part of constructing the string value, or use USING
, as illustrated in Section 43.5.4.
Variable substitution currently works only in SELECT
, INSERT
, UPDATE
, DELETE
, and commands containing one of these (such as EXPLAIN
and CREATE TABLE ... AS SELECT
), because the main SQL engine allows query parameters only in these commands. To use a non-constant name or value in other statement types (generically called utility statements), you must construct the utility statement as a string and EXECUTE
it.
The PL/pgSQL interpreter parses the function's source text and produces an internal binary instruction tree the first time the function is called (within each session). The instruction tree fully translates the PL/pgSQL statement structure, but individual SQL expressions and SQL commands used in the function are not translated immediately.
As each expression and SQL command is first executed in the function, the PL/pgSQL interpreter parses and analyzes the command to create a prepared statement, using the SPI manager's SPI_prepare
function. Subsequent visits to that expression or command reuse the prepared statement. Thus, a function with conditional code paths that are seldom visited will never incur the overhead of analyzing those commands that are never executed within the current session. A disadvantage is that errors in a specific expression or command cannot be detected until that part of the function is reached in execution. (Trivial syntax errors will be detected during the initial parsing pass, but anything deeper will not be detected until execution.)
PL/pgSQL (or more precisely, the SPI manager) can furthermore attempt to cache the execution plan associated with any particular prepared statement. If a cached plan is not used, then a fresh execution plan is generated on each visit to the statement, and the current parameter values (that is, PL/pgSQL variable values) can be used to optimize the selected plan. If the statement has no parameters, or is executed many times, the SPI manager will consider creating a generic plan that is not dependent on specific parameter values, and caching that for re-use. Typically this will happen only if the execution plan is not very sensitive to the values of the PL/pgSQL variables referenced in it. If it is, generating a plan each time is a net win. See PREPARE for more information about the behavior of prepared statements.
Because PL/pgSQL saves prepared statements and sometimes execution plans in this way, SQL commands that appear directly in a PL/pgSQL function must refer to the same tables and columns on every execution; that is, you cannot use a parameter as the name of a table or column in an SQL command. To get around this restriction, you can construct dynamic commands using the PL/pgSQL EXECUTE
statement — at the price of performing new parse analysis and constructing a new execution plan on every execution.
The mutable nature of record variables presents another problem in this connection. When fields of a record variable are used in expressions or statements, the data types of the fields must not change from one call of the function to the next, since each expression will be analyzed using the data type that is present when the expression is first reached. EXECUTE
can be used to get around this problem when necessary.
If the same function is used as a trigger for more than one table, PL/pgSQL prepares and caches statements independently for each such table — that is, there is a cache for each trigger function and table combination, not just for each function. This alleviates some of the problems with varying data types; for instance, a trigger function will be able to work successfully with a column named key
even if it happens to have different types in different tables.
Likewise, functions having polymorphic argument types have a separate statement cache for each combination of actual argument types they have been invoked for, so that data type differences do not cause unexpected failures.
Statement caching can sometimes have surprising effects on the interpretation of time-sensitive values. For example there is a difference between what these two functions do:
and:
In the case of logfunc1
, the PostgreSQL main parser knows when analyzing the INSERT
that the string 'now'
should be interpreted as timestamp
, because the target column of logtable
is of that type. Thus, 'now'
will be converted to a timestamp
constant when the INSERT
is analyzed, and then used in all invocations of logfunc1
during the lifetime of the session. Needless to say, this isn't what the programmer wanted. A better idea is to use the now()
or current_timestamp
function.
In the case of logfunc2
, the PostgreSQL main parser does not know what type 'now'
should become and therefore it returns a data value of type text
containing the string now
. During the ensuing assignment to the local variable curtime
, the PL/pgSQL interpreter casts this string to the timestamp
type by calling the textout
and timestamp_in
functions for the conversion. So, the computed time stamp is updated on each execution as the programmer expects. Even though this happens to work as expected, it's not terribly efficient, so use of the now()
function would still be a better idea.